16. Setting Up Fault Management Configuring Event Parsers
900
AlliedView NMS Administration Guide
FIGURE 16-5 Setting the Event Parser to Produce Alarms for SYSLOG
The usual scenario would be the device in the Physical Network view would show the device has a major alarm. Right
clicking Alarms/Events -> Alarms on the affected device would show Figure 16-6. (This would also show up in the Events view
as a network event.). The user could then double click the alarm row to further process the alarm, or Edit -> Clear to clear
the alarm.
FIGURE 16-6 Alarm Produced as a Result of Configuring Event Parser
16.4.4 Changing Severity of Default Events (i.e. Status Update Failure)
The default Event Parser Configuration Form allows the user to view and modify the events that are generated by the
devices. As explained in 16.4, these events have attributes (especially the alarm level) that should not be changed unless with
consultation with Allied Telesis personnel.
For default events (such as status update failure), the severity of the event is already set, but can be changed by creating an
Event Parser that outputs a different Severity Alarm. Following is an overview of status update and the steps to change the
severity of a status node failure from Major to Critical.
16.4.4.1 Overview
The AlliedView NMS periodically tests connectivity to all managed devices by polling their interfaces. By default, the period is
300 seconds, which can be modified with the Managed Object Properties dialogue (by changing the pollInterval parameter).