10. Card Management GE3 Card
297
AlliedView NMS Administration Guide
10.11 GE3 Card
After selecting a GE3, the user can select View Details, which provides specific information on the card and includes some of
the same options available on the Card Management table. Refer to Figure 10-4 and Table 10-1.
FIGURE 10-4 GE3 Card Details
10.12 GE8 Card
The attributes and options are the same as for the GE3 card except that the GE8 has a software load, described in GE3 Card.
TABLE 10-1 GE3 Card Details
Field/Button Description
Device The device name and the slot number for the card (0 or 1 for the iMAP 9400, 10 or 11
for the iMAP 7700.
Admin. State If UP, the GE3 is capable of providing service. If DOWN, can Run Diags.
Oper. State The GE3 is providing service. This state is not controllable but depends on the Admin.
State.
Status The current state of the card. States can be static or dynamic (transition of state such as
Initializing or Running Tests).
Profile The template for provisioning data. The default is AutoProv. If the blank pull-down is
chosen, there is no profile (manually provisioned).
Modify Activated when the Profile is changed.
Disable Disables the card. Active only when the Admin State is UP.
Enable Enables the card. Active only when the Admin State is DOWN.
Restart Reboots the card. For the GE1, there is no software load.
Run Diags Runs diagnostics. Active only when the Admin state is DOWN, so must Disable first.