12. Port Management - non-iMAP Devices Support of CWMP with TR-069 Devices
442
AlliedView NMS Administration Guide
4. Uncheck the Save Only checkbox. Click on OK.
5. The CPE Connection dialog box opens Figure 12-23). Click OK. (Default Password is 12345.)
FIGURE 12-23 Comtrend CPE Connection Dialog Box
6. The configuration file is uploaded to the Comtrend device, the device reboots, and the device is now ready to be
deployed.
12.6.9 Example Procedure - Provisioning
At an NMS client on the network, the Comtrend is provisioned as follows:
1. Bring up the Triple Play form for Bonded ports, as explained in 11.1. Refer to Figure 12-24.
2. For the Comtrend device, you must enter a Description (Customer ID) of 15 characters or less. If more than 15
characters are used, the iMAP ADSL bond port will use the entire string, but the Comtrend CPE SysContact will be
truncated to15 characters, resulting in more complex customer management.
3. For the Comtrend device, you must fill in the MAC address, found at the bottom of the Comtrend.
4. Do not use the Derived Voice-related fields, since derived voice will not be managed by the NMS (refer to 12.6.3). Note:
You may provision a POTS line.
5. Click on Provision. The Comtrend device is added to the iMG/RG table, but the IP address remains 0.0.0.0 until the
Comtrend device is physically connected to the network.