Chapter 17: SNMPv3
250 Section III: SNMPv3
Note
Enter a value for the Message Processing Model field only if you
select SNMPv1 or SNMPv2c as the Security Model. If you select the
SNMPv3 protocol as the Security Model, then the switch
automatically assigns the Message Processing Model to SNMPv3.
5. In the Message Processing Model field, enter a Security Model that is
used to process messages.
Select one of the following SNMP protocols:
v1
Select this value to process messages with the SNMPv1 protocol.
v2c
Select this value to process messages with the SNMPv2c protocol.
v3
Select this value to process messages with the SNMPv3 protocol.
6. In the Security Model field, select one of the following SNMP protocols
as the Security Model for this Security Name, or User Name.
v1
Select this value to associate the Security Name, or User Name, with
the SNMPv1 protocol.
v2c
Select this value to associate the Security Name, or User Name, with
the SNMPv2c protocol.
v3
Select this value to associate the Security Name, or User Name, with
the SNMPv3 protocol.
7. In the Security Name field, enter a User Name that you previously
configured with the SNMPv3 User Table.
See “Creating a User Table Entry” on page 206.
8. In the Security Level field, select one of the following Security Levels:
Note
The value you configure for the Security Level must match the value
configured for the User Name in the SNMPv3 User Table Menu. See
“Creating a User Table Entry” on page 206.
No Authentication/Privacy
This option represents neither an authentication nor privacy protocol.