AT-S63 Management Software Web Browser User’s Guide
Section III: SNMPv3 219
Included
Enter this value to permit the View Name to see the subtree specified
above.
Excluded
Enter this value to not permit the View Name to see the subtree
specified above.
7. In the Storage Type field, enter a storage type for this table entry:
Volatile
Select this storage type if you do not want the ability to save an entry in
the Target Parameters Table. After making changes to an Target
Parameters Table entry with a Volatile storage type, the Save Config
option is not displayed on the Configuration menu.
NonVolatile
Select this storage type if you want the ability to save an entry in the
View Table. After making changes to a View Table entry with a
NonVolatile storage type, the Save Config option is displayed on the
Configuration menu. Allied Telesis recommends this storage type.
Note
The Row Status parameter is a read-only field in the web browser
interface. The Active value indicates the SNMPv3 View Table entry
takes effect immediately.
8. Click Apply.
9. To permanently save your changes, select the Save Config option in
the Configuration menu.