Chapter 17: SNMPv3
218 Section III: SNMPv3
2. Select the SNMP tab.
The SNMP tab is shown in Figure 75 on page 204.
3. In the SNMPv3 section, click the button next to Configure View Table
and then click Configure at the bottom of the tab.
The SNMPv3 View Table tab is shown in Figure 79 on page 215.
4. Click the button next to the SNMPv3 View Table entry to be changed
and then click Modify.
The Modify SNMPv3 View page is shown in Figure 81.
Figure 81. Modify SNMPv3 View Page
5. In the Subtree Mask field, enter a subtree mask in hexadecimal format.
This is an optional parameter that is used to further refine the value of
the Subtree OID parameter.
The Subtree OID parameter defines a MIB View and the Subtree Mask
parameter further restricts a user’s view to a specific the column and
row of the MIB View. The value of the Subnet Mask parameter is
dependent on the subtree you select. For example, if you configure the
View Subtree parameter as MIB ifEntry.0.3, it has the following value:
1.3.6.1.2.1.2.2.1.0.3
To restrict the user’s view to the third row (all columns) of the MIB
ifEntry.0.3, enter the following value for the Subtree Mask parameter
ff:bf
6. In the View Type field, enter one of the following view types: