Allied-telesis AT-S62 Bedienungsanleitung Seite 77

  • Herunterladen
  • Zu meinen Handbüchern hinzufügen
  • Drucken
  • Seite
    / 420
  • Inhaltsverzeichnis
  • LESEZEICHEN
  • Bewertet. / 5. Basierend auf Kundenbewertungen
Seitenansicht 76
AT-S62 Command Line User’s Guide
77
CREATE SNMP COMMUNITY
Syntax
create snmp community=”community
[access=read|write] [open=yes|no]
[traphost=ipaddress] [manager=ipaddress]
Parameters
community Specifies a new community string. The maximum
length of a community string is 15 alphanumeric
characters. Spaces are allowed. The name must be
enclosed in double quotes if it includes a space.
Otherwise, the quotes are optional. The string is case
sensitive.
access Specifies the access level of the new community
string. Options are “read” for read only access and
“write” for both read and write access. The default is
“read.”
open Specifies the open or closed status of the community
string. The options are:
yes The community string is open, meaning
any management workstation can use the
string to access the switch. The values are
equivalent.
no The community string is closed, meaning
only those management workstations
whose IP addresses are assigned to the
string can use it to access the switch. You
can assign a management IP address to the
string using the MANAGER option in this
command. The default setting for a
community string is closed. The values are
equivalent.
traphost Specifies the IP address of a trap receiver to receive
system traps.
Seitenansicht 76