Chapter 17: IGMP Snooping Commands
232
SET IP IGMP
Syntax
set ip igmp [snoopingstatus=enabled|disabled]
[hoststatus=singlehost|multihost] [timeout=value]
[numbermulticastgroups=value]
[routerport=port|all|none|auto]
Parameters
snoopingstatus Activates and deactivates IGMP snooping
on the switch. Possible settings are:
enabled Activates IGMP snooping.
disabled Deactivates IGMP snooping.
This is the default setting
hoststatus Specifies the IGMP host node topology.
Options are:
singlehost Activates the Single-Host/Port
setting, which is appropriate
when there is only one host
node connected to a port on
the switch. This is the default
setting.
multihost Activates the Multi-Host
setting, which is appropriate if
there is more than one host
node connected to a switch
port.
timeout Specifies the time period, in seconds, used
by the switch in determining inactive host
nodes. An inactive host node is a node that
has not sent an IGMP report during the
specified time interval. The range is 1 to
86,400 seconds (24 hours); the default is
260 seconds.