8 Software Reference
General PIM-DM
information
The following commands display general PIM-DM information.
PIM-DM timers Timers for PIM-DM operations have defaults that suit most networks and
should not generally be modified.
Caution Changing these timers to inappropriate values can cause PIM to
function in undesirable ways. System administrators should change these timer
values based on a sound understanding of their interaction with other devices
in the network.
If the timers need to be modified, use the command:
set pim [jpinterval={1..65535|default}]
[keepalivetime={10..65535|default}]
[pruneholdtime={1..65535|default}]
[sourcealivetime={10..65535|default}]
[srinterval={10..255|default}] [other-options...]
To list the values of the global PIM timers, use the command:
show pim timer
PIM-DM debugging To display debugging information about PIM-DM, use the command:
enable pim debug={all|assert|bsr|c-rp-adv|graft|hello|joint|
register|staterefresh}[,...]
To see which debugging options are enabled, use the command:
show pim debug
This command... Shows...
show pim config CLI commands that make up the switch’s PIM configuration.
show pim counters the number of PIM messages that the switch has received and
sent, and the number of bad messages it has received.
show pim neighbour information about the neighbouring switches that PIM is aware
of.
show pim route the internal PIM routing table.
show pim staterefresh the internal State Refresh table.