Allied-telesis AT-S94 CLI (AT-8000S Series) Bedienungsanleitung Seite 202

  • Herunterladen
  • Zu meinen Handbüchern hinzufügen
  • Drucken
  • Seite
    / 402
  • Inhaltsverzeichnis
  • LESEZEICHEN
  • Bewertet. / 5. Basierend auf Kundenbewertungen
Seitenansicht 201
Page 201
Allied Telesis
AT-8000S-S94-3.0 Command Line Interface Users Guide
Example
The following example displays the estimated copper cable length attached to all ports.
show fiber-ports optical-transceiver
Use The show fiber-ports optical-transceiver User EXEC mode command displays the optical transceiver
diagnostics.
Syntax
show fiber-ports optical-transceiver [ interface ] [detailed]
Parameters
inteface — A valid Ethernet port. (Full syntax: unit/port)
detailedDisplays a detailed diagnostics
Default Configuration
This command has no default configuration.
Command Mode
User EXEC mode
User Guidelines
There are no user guidelines for this command.
Example
The following example displays the estimated copper cable length attached to all ports.
console>
show copper-ports cable-length
Port Length [meters]
---- ---------------------
1/e1 < 50
1/e2 Copper not active
1/e3 110-140
1/e4 Fiber
console>
show fiber-ports optical-transceiver
Power
Port Temp Voltage Current Output Input TX LOS
Fault
------ ------ ------- ------- ------- ----- ------ -----
7/e1 W OK E OK OK OK OK
7/e2 OKOKOKOKOKE OK
Seitenansicht 201