Port a1 Port a1 command reference
iMG/RG Software Reference Manual (ADSL Port)
8-20
MaxDownRate Group A and Group C devices
Set the maximum downstream rate in bits per
seconds
511
MaxInterleaveD Group A and Group C devices
Sets the Max interleaved Depth
Possible values are:
64, 128, 256, 511
511
MaxRSMemory ONLY Group B devices
Configures the Size of RS Memory
Possible values are:
16, 24, 32, 48
32
MaxSNRMargin Group A and Group C devices
SNR Margin
Possible values are:
Enable, Disable
Disable
MemorizedConnec-
tion
Group A and Group C devices
Possible values are:
Enable, Disable
Disable
NTRMode Group A and Group C devices
PMmode Possible values are:
L2L3NotAllowed, L3NotAllowed, L2L3Allowed
L2L3Allowed
PSDMask Group A and Group C devices
PhysicalPort Physical port of the PCU that is to be used for
Data transfer.
0
Profile Configures the Profile to be used
Possible values are:
MAIN, BT, SPAIN, SBC, COVAD, BRAZIL, MII,
KT, TELSTRA, XR, HAN, FRANCE, FINLAND
a,
FASTWEB, RESERVED
MAIN
TABLE 8-2 Options for ADSL Port Attributes (Continued)
Option Description Default Value