Powering on a Switch with an AC Power Supply Module
To power on a switch with an AC Power Supply Module, perform the
following procedure:
1. Position the power cord retaining clip in the up position, as shown in
Figure 57. Note that the AT-PWR1200 power supply does not have a
retaining clip.
Figure 57. Power Cord Retaining Clip in the Up Position
2. Plug the power cord into the AC power conne
ctor on the rear panel of
the unit, as shown in Figure 58. Lower the power cord retaining clip to
secure the power cord to the unit.
Figure 58. Connecting the AC Power Cord
3. Connect the other end of the power cord to an appropriate AC power
outlet. For power specifications for the switch, refer to “Power
Specifications” on page 114.
Warning: Power cord is used as a disconnection device. To de-
energize equipment, disconnect the power cord.