Allied Telesyn AT-VIEW PLUS
DEVICE MANAGEMENT
Displays configuration and state information for a bi-directional Virtual Path Link.
Note - The Virtual Path Link (VPL) sub-menu option does not display the correct
parameters. Instead, it displays the sub-menu option name as a parameter with a value of
'noSuchName'.
Virtual Channel Link (VCL)
Displays configuration and state information for a bi-directional Virtual Channel Link.
Note - AT-AR240E : The current firmware version does not allow the following parameters
to be configured:
Administrative Status
Receive Traffic Descriptor Index
Transmit Traffic Descriptor Index
AAL Type
AAL5 CPCS Transmit SDU Size
AAL5 CPCS Receive SDU Size
AAL5 Encapsulation Type
Attempting to configure these parameters will result in the error message: "The error
occurred with 'Set' operation. Error: gen Error".
Note - AT-AR240E: The Port Number parameter and the Virtual Channel Link (VCL)
parameters are not relevant and should be ignored.
Note - AT-AR240E : The current firmware version does not allow the Status parameters to
be configured. Attempting to configure them will result in the error message: "The error
occurred with 'Set' operation. Error: bad value." or "The error occurred with 'Set' operation.
Error: gen Error".
Note - AT-AR250E/AT-AR255E : The Virtual Channel Link (VCL) sub-menu option does
not display the correct parameters. Instead, it displays the sub-menu option name as a
parameter with a value of 'noSuchName'.
Virtual Path (VP) Cross Connect
Displays configuration and state information of all point-to-point , point-to-multipoint, or
multipoint-to-multipoint VP cross connect.
Note - The Virtual Path (VP) Cross Connect sub-menu option does not display the correct
parameters. Instead, it displays the sub-menu option name as a parameter with a value of
'noSuchName'.
Virtual Channel (VC) Cross Connect
Displays configuration and state information of a bi-directional VC cross connect.