Chapter 17: SNMPv3 Configuration
Section III: SNMPv3 Protocol 322
The text format is for TCP/IP is:
tcp
The following prompt is displayed:
Enter View Type [I-Included, E-Excluded]:
7. Choose one of the following view types:
I - Included
Enter this value to permit a user to see the subtree specified
above.
E - Excluded
Enter this value to not permit a user to see the subtree specified
above.
8. After making changes, type R until you return to the Main Menu. Then
type S to select Save Configuration Changes.
Modifying a Storage Type
To modify the Storage Type parameter in an SNMPv3 View Table entry,
perform the following procedure.
1. Follow steps 1 through 5 in the procedure described in Creating an
SNMPv3 User Table Entry on page 305. Or, from the Main Menu type
5->1->1->8->5.
The Configure SNMPv3 Table Menu is shown in Figure 101 on
page 306.
2. From the Configure SNMPv3 Table Menu, type 3 to select Configure
SNMPv3 View Table.
The Configure SNMPv3 View Table Menu is shown in Figure 104
on page 316.
3. From the Configure SNMPv3 View Table Menu, type 3 to select
Modify SNMPv3 Table Entry.
The Modify SNMPv3 Table Menu is shown in Figure 105 on page
320.
4. To modify the storage type, type 3 to select Set Storage Type.
The following prompt is displayed:
Enter View Name:
5. Enter the View Name you want to modify.
The following prompt is displayed:
Enter View Subtree (OID format/Text Name):