Secure the Entrance (Replace/Seal the Grommet and Install Tie-Down)
1. Take the grommet that you removed and cut a notch at the bottom so that the drop and ground
wire can go through when the grommet is replaced.
2. Place the grommet back (with the notch at the bottom) and seal the grommet with tape (not
provided) and silicone sealant (not provided). Refer to Figure 19.
Caution
The grommet must be sealed so that the unit can operate correctly in an outside environment.
3. Insert a UV-rated wire tie (not provided) through the slots at the bottom of the entrance as shown in
Figure 19.
Figure 19. Sealing Grommet and Inserting Tie-Down
4. Secure the fiber cable and ground wire to the enclosure by wrapping the wire tie around the cords and
cutting off the excess wire tie.
Connect the Ground
1. Connect the other end of the ground wire to the building’s grounding electrode, according to local and
national electrical codes.