Seitenansicht 96
Converteon Management Software User’s Guide
97
Figure 25. Viewing the OAM Client Status
If the third character is a “o”, the fiber optic port has not established
a connection to the port on the other line card. Try the following:
Check that the fiber optic cable is firmly connected to the ports
on the two cards.
Check that the other Converteon chassis is powered on and
that the line card is fully inserted in the slot in the enclosure.
If the cards are AT-CM3 Line Cards set to the MissingLink and
OAM mode or the Smart MissingLink and OAM mode, check to
be sure that their twisted pair ports are connected to live
network equipment.
If the third character is a letter, such as an “L” or “P”, the fiber optic
port has established a link with the other line card and the OAM
client is attempting to negotiate with the other client. If the
character does not transition to an asterisk, it probably means that
the OAM settings on one or both of the cards is incorrect. To verify
their settings, repeat the procedures “Setting the Operating Mode”
on page 90 and “Configuring the OAM Settings” on page 93.
8. To test the dying gasp feature, do the following:
a. Power off the AT-CV1203 Chassis. If the chassis has two power
supplies, disconnect one of the supplies, wait a second or two and
power off the second supply.
Module Status and Configuration
Converteon
======================== MODULE_INFO ======================= ========== FIBER_PORT ========== ======== COPPER_PORT ========
Mod_Name CardTypeVer ST OperMod IPC FrmSz LPM AC VER ST SP FC IngRL EgrRL OAM ST SP FC IngRL EgrRL AN
1 ------ AT-CV5M02 * Active 800 ---- ON_ V400 - --- - ----- ---- --- * 100 - ----- ----- -
2 Reg11 AT-CM302 * OAM_LT o*o 10240 ON_ N V400 * 100 Y 0 0 oo* * 100 Y 0 0 Y
3 Reg20 AT-CM302 * OAM_LT o*o 10240 ON_ N V400 * 100 Y 0 0 oo* * 100 Y 0 0 Y
4 Reg21 AT-CM302 * OAM_LT o*o 10240 ON_ N V400 * 100 Y 0 0 oo* * 100 Y 0 0 Y
5 Area2a AT-CM302 * OAM_ML o*o 10240 ON_ N V400 * 100 Y 0 0 oo* * 100 Y 0 0 Y
6 Area2b AT-CM302 * LT ___ o*o 10240 ON_ N V400 * 100 Y 0 0 --- * 100 Y 0 0 Y
7 a121 AT-CM3K0S * OAM_LT o** 10240 ON_ N V400 * 1G Y 0 0 oo* * 1G Y 0 0 Y
8 Reg12 AT-CM202-v2 * OAM_V o*o ---- --- N V400 * 100 Y 0 0 oo* * 100 Y 0 0 Y
9 AT-CM202-v2 * OAM_V o*o ---- --- N V400 * 100 Y 0 0 oo* * 100 Y 0 0 Y
10 AT-CM202-v2 * OAM_V o*o ---- --- N V400 * 100 Y 0 0 oo* * 100 Y 0 0 Y
11 AT-CV102 * LT ___ --- ---- --- * ---- * 100 --- ---- ---- --- * 100 -- ----- -----
12 AT-CV102 * LT ___ --- ---- --- * ---- * 100 --- ---- ---- --- * 100 -- ----- -----
13 AT-CV102 * LT ___ --- ---- --- * ---- * 100 --- ---- ---- --- * 100 -- ----- -----
14 AT-CV102 * LT ___ --- ---- --- * ---- * 100 --- ---- ---- --- * 100 -- ----- -----
15 AT-CV102 * LT ___ --- ---- --- * ---- * 100 --- ---- ---- --- * 100 -- ----- -----
More ...
Return to Main Menu ...
OAM Status - Operational
oo*