Converteon Management Software User’s Guide
269
Config
Revision
Indicates the current revision of the Information TLV. The
value of this field starts at zero and be incremented each
time something in the Information TLV changes. Upon
reception of an Information TLV from a peer, an OAM
Client may use this field to decide if it needs to be
processed (an Information TLV that is identical to the
previous Information TLV doesn't need to be parsed as
nothing in it has changed).
Vendor
Information
Indicates the 32-bit identifier that may be used to
differentiate a vendor’s product models/versions.
Vendor OUI Contains the Organizationally Unique Identifier (OUI) of
00-30-84 for Allied Telesis.
Loopback
State
Indicates the current loopback state of the OAM client.
NoneNo loopback initiated.
Initiating Loopback – The local OAM client is initiating
a loopback test with the remote client.
Remote in Loopback – The remote OAM client has
received the loopback command from the local client
and is ready to participate or is already participating
in the loopback test.
Terminating Loopback – The local OAM client is
ending the loopback test.
In Loopback
Tes t
Indicates whether or not the OAM client is currently
running a loopback test.
Yes – The OAM client is running a loopback test.
No – The OAM client is not running a loopback test.
Table 32. Show Local OAM Information Window