AT-S63 Management Software Web Browser Interface User’s Guide
Section III: SNMPv3 255
Figure 98. Modify SNMPv3 Access Page
Note
The Context Prefix field is a read-only field. The Context Prefix field
is always set to null.
6. In the Read View Name field, enter a value that you configured with
the View Name parameter in the View Table.
This parameter allows the users assigned to this Group Name to view
the information specified by the View Table entry. This value does not
need to be unique.
7. In the Write View Name field, enter a value that you configured with the
View Name parameter in the View Table.
This parameter allows the users assigned to this Security Group to
write, or modify, the information in the specified View Table. This value
does not need to be unique.
8. In the Notify View Name field, enter a value that you configured with
the View Name parameter in the View Table.
This parameter allows the users assigned to this Group Name to send
traps permitted in the specified View. This value does not need to be
unique.