Table 3 Twisted Pair Port Specifications
q Refer to Table 4 and Table 5 for the fiber optic cabling specifications.
Table 4 Fiber Optic Port Specifications (Full-duplex)
Table 5 Fiber Optic Port Specifications (Half-duplex)
Reviewing Safety Precautions
Please review the following safety precautions before you begin to install the
media converter.
Model Cable Maximum Operating Distance
All models Shielded Category 3 or better 100 m (328 ft)
Model Connector Cable
Maximum Operating
Distance
1
1. Maximum operating distance over multimode fiber is 2 km (1.2 mi) if the maximum measured optical loss budget
is less than 20 dB’s when measured at 850 nm optical wavelength.
Maximum
Allowable Loss
Budget
AT-MC13 ST 62.5/125 micron
multimode
2 km (1.2 mi) 20 dB at 850 nm
AT-MC14 SC 62.5/125 micron
multimode
2 km (1.2 mi) 20 dB at 850 nm
Number of Media Converters Connected Devices
Maximum Operating
Distance
One Media Converter Inline Switch to Switch 372 m (1,221 ft)
Workstation to Switch 372 m (1,221 ft)
Switch to Class I Repeater 137 m (450 ft)
Switch to Class II Repeater 185 m (607 ft)
Two Media Converters Inline Switch to Switch 332 m (1,089 ft)
Workstation to Switch 332 m (1,089 ft)
Switch to Class I Repeater 97 m (318 ft)
Switch to Class II Repeater 145 m (476 ft)