Chapter 14: GVRP
192
Time Settings
Perform the following procedure to configure the GVRP port settings:
1. From the main menu on the left side of the page, select Bridge.
The Bridge folder expands.
2. From the Bridge folder, select GVRP.
The GVRP folder expands.
3. From the GVRP folder, select Time Settings.
The AT-GS950/48 GVRP Time Settings Page is displayed. See Figure
70 for a partial view of this page.
Figure 70. AT-GS950/48 GVRP Time Settings Page
Note
The GARPLeaveTimer must be greater than (GARPJoinTimer x2 +
10) and the GARPLeaveAllTimer must be greater than
(GARPLeaveTimer + 10). The acceptable input values are multiples
of 10. If you try to enter a value that is not a multiple of 10, the value
is rounded down.
4. The following fields are listed for each port:
Port - This parameter displays the ports on the switch.
JoinTime - This parameter is the GARP Join Timer. Its range is 10
- 1073741810 milli-seconds.