Chapter 6: Temperature and Fan Control Commands
120
Figure 34 shows an example of the information that the command displays
when the switch is a stack master.
Figure 34. SHOW SYSTEM ENVIRONMENT Command
The columns in the display are described here:
Example
The following example displays environmental information for the switch:
Environment Monitoring Status
----------------------------------------------------------------
Switch Model: AT-8100S/24 Stack Member Type: Master
----------------------------------------------------------------
ID Sensor (Units) Reading Status
----------------------------------------------------------------
0 PSU 1 On Normal
1 PSU 2 Off Off
----------------------------------------------------------------
----------------------------------------------------------------
Switch Model: AT-8100S/16F8-SC Stack Member Type: Slave 3
----------------------------------------------------------------
ID Sensor (Units) Reading Status
----------------------------------------------------------------
0 Temp (Degrees C) 37 Normal
1 Fan 1 (RPM) 3467 Normal
2 PSU 1 On Normal
3 PSU 2 Off Off
Table 7. SHOW SYSTEM ENVIRONMENT Command
Parameter Description
Switch Model Indicates a model name of the switch.
Stack Member Type Indicates a role of the switch as a stacking
member. This parameter is only
applicable for a stacking member.
ID Indicates the ID number of an item.
Sensor (Units) Indicates an item on the switch, such as
temperature, fan, or power supply unit
(PSU).
Reading Indicates the current reading of the item.
Status Indicates the status of the item.