AT-RPS3000 Redundant Power Supply Installation Guide
77
3. Remove the cable from the RPS port.
Be sure to remove the RPS cable squarely and evenly from the
connector on the chassis. Removing the connector at an angle may
cause an electrical short that might damage the device.
Figure 57. Removing the AT-RPS-CBL1.0 Cable from the AT-RPS3000
Chassis
4. Loosen the two thumbscrews that secure the cable to the RPS port on
the x610 Series switch.
5. Remove the cable from the RPS port on the switch.
Be sure to remove the RPS cable squarely and evenly from the
connector on the switch. Removing the connector at an angle may
cause an electrical short that might damage the device.