Quick Install Guide 5
C613-04040-01 REV C
5. Place the AT-RPS9000 in its operating location.
If installing the RPS on a desktop:
• Make sure the RPS’s rubber feet are attached.
If installing the RPS in a rack:
• Remove the rubber feet.
• Attach the rack-mounting brackets.
• Mount the RPS in the rack.
For more information on selecting a site, see “Selecting a Site” on page 3.
6. Install the AT-PWR9000 power unit (if not already installed).
• In an antistatic environment, remove the AT-PWR9000 from its packing
material. Be sure to observe ESD precautions.
• On the AT-RPS9000 chassis, choose an empty bay and remove its blank
faceplate by loosening the two Phillips screws until they disengage
from the chassis (see Figure 1 on page 5).
Keep the faceplate for future use. If you remove a power unit, replace the faceplate to
prevent dust and debris from entering the AT-RPS9000 chassis and to maintain proper
airflow.
The AT-RPS9000 and other AT-PWR9000 units may overheat or be damaged by
dust and debris if bays are left uncovered.
• Slowly and carefully slide the power unit into the chassis.
• Firmly press the power unit home (until its front panel engages or
nearly engages the chassis).
• Tighten the two Phillips screws on the power unit’s faceplate.
Figure 1: Captive mounting screws on the AT-PWR9000
Handle
Captive Screws
9
9
9
9