CentreCOM AT-MR420TRAT-MR820TR Multiport Micro Repeaters Installation Guide PN 613-10625-00 Rev A ® MRx20TR(STP/UTP)_BookA Page i Thursday, April 3

Seite 2

x ISTRUZIONI PER IL MONTAGGIOATTENZIONE : questi modelli sono concepiti per il funzionamento in posizione ORIZZONTALE. NON È POSSIBILE EFFETTUARE IL

Seite 3 - Requirements

xi FORSIKTIG: MEKANISK LASTNING Installering av utstyret på hyllen må utføres på slik måte at ingen farlige situasjoner oppstår som en følge av uj

Seite 4

xiiINSTRUÇÕES DE INSTALAÇÃOCUIDADO: Este modelos foram projetados para funcionar na posição HORIZONTAL. NÃO DEVE SER EFETUADA INSTALAÇÃO VERTICAL sem

Seite 5

xiiiINSTRUCCIONES DE MONTAJEATENCION: Estos modelos están diseñados para operar en posición HORIZONTAL. NO SE DEBEN MONTAR VERTICALMENTE sin el uso

Seite 6

xivMONTERINGSINSTRUKTIONERVARNING: Dessa modeller är konstruerade för användning i HORISONTALLÄGE. VERTIKALMONTERING får EJ UTFÖRAS utan att ett Allie

Seite 7

xvTable of ContentsElectrical Safety and Installation Requirements . . . . . . . . . . . . . . . . . .iiiAbout This Guide . . . . . . . . . . . . .

Seite 8

xviChapter 3Connectivity . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 15Four Media Connectors.

Seite 9

xviiAppendix DCentreCOM AT-MR420TR/AT-MR820TR Guide Feedback . . . . . . . . . 45Appendix EWhere To Find Us . . . . . . . . . . . . . . . . . . . .

Seite 10

MRx20TR(STP/UTP)_BookA Page xviii Thursday, April 3, 1997 5:24 PM

Seite 11

xixAbout This GuideThis guide is written for system administrators who are responsible for configuring, monitoring, and maintaining a Local Area Netwo

Seite 12

Copyright  1997 Allied Telesyn International Corp.All rights reserved. No part of this publication may be reproduced without prior written permissi

Seite 13

About This GuidexxDocument ConventionsThe following conventions are used in presenting information in this guide: NoteA note provides additional info

Seite 14

AT-MR420TR and AT-MR820TR Installation GuidexxiThe process is straightforward: Once the BBS is accessed, it requests that you register either as a new

Seite 15 - Table of Contents

MRx20TR(STP/UTP)_BookA Page xxii Thursday, April 3, 1997 5:24 PM

Seite 16

1Chapter 1Product DescriptionOverviewAllied Telesyn’s multiport AT-MR420TR/AT-MR820TR Micro Repeaters represent a compact, inexpensive solution for Lo

Seite 17

Product Description2Figure 1: AT-MR420TR and AT-MR820TR Front PanelsFigure 2: AT-MR420TR and AT-MR820TR Rear PanelsOn the back panel are four/eight ST

Seite 18

AT-MR420TR and AT-MR820TR Installation Guide3FeaturesThe AT-MR420TR/AT-MR820TR Micro Repeaters have incorporated the latest technologies, including a

Seite 19 - About This Guide

Product Description4jabber lock-up automatically prevents transmitted data from reaching the repeater if the transmitted data time exceeds a specified

Seite 20 - Document Conventions

AT-MR420TR and AT-MR820TR Installation Guide5❑ 10Base5 (Attachment Unit Interface [AUI])— Located to the right of the BNC port, the 10Base5 network po

Seite 21

Product Description6Backbone Enable SwitchThis dual-position switch allows you to activate the backbone network AUI and BNC ports. When this switch i

Seite 22

7Chapter 2InstallationSite RequirementsVentilationAT-MR420TR/AT-MR820TR Micro Repeaters have grilled openings on both sides for ventilation. Although

Seite 23 - Product Description

iii Electrical Safety and Installation Requirements STANDARDS: This product meets the following standards RFI Emission : EN55022 Class A WARNING:

Seite 24

Installation8Quick Installation 1. Carefully remove the AT-MR420TR/AT-MR820TR Micro Repeaters from their packaging materials. Keep the packing materia

Seite 25 - Features

AT-MR420TR and AT-MR820TR Installation Guide9ConnectionsThe AT-MR420TR/AT-MR820TR Micro Repeaters have the following connectors:❑ RJ45❑ AUI❑ BNCRJ45 P

Seite 26 - Backbone Network Port

Installation10LED Status IndicatorsThe front panel indicators are grouped into the following categories:❑ Network Load❑ Port Status❑ Hub StatusNetwork

Seite 27

AT-MR420TR and AT-MR820TR Installation Guide11 NoteA data packet is too fast for the human eye to distinguish on an LED, therefore the LEDs will not

Seite 28

Installation12If there is no link light, there is no signal continuity.Check that the attached Data Terminal Equipment (DTE) is ON and that the proper

Seite 29 - Installation

AT-MR420TR and AT-MR820TR Installation Guide131 Occasional collisions are normal in Ethernet networks. A constantly illuminated Collision LED may indi

Seite 30 - Quick Installation

Installation14 NoteThe LINK LED validates the receive pair only. The opposite end of the STP segment is responsible for validating the transmit pair.

Seite 31 - Connections

15Chapter 3ConnectivityFour Media ConnectorsThis repeater has four types of ports and media connectors:❑ AC input power connector❑ 10Base5 (AUI) netwo

Seite 32 - LED Status Indicators

Connectivity16Figure 8: Power ConnectorMRx20TR(STP/UTP)_BookA Page 16 Thursday, April 3, 1997 5:24 PM

Seite 33

AT-MR420TR and AT-MR820TR Installation Guide1710Base-T Network SpecificationsTable 2 provides an overview of the IEEE 802.3 specifications for 10Base-

Seite 34

iv INSTALLATIONELECTRICAL —AUTO VOLTAGE ADJUSTMENT This product will automatically adjust to any voltage between the ranges shown on the label. ELEC

Seite 35 - System Check

Connectivity18Figure 9: AUI Network Port10Base5 (Thick) Ethernet Cable. When configuring 10Base5 coax segments, IEEE 802.3 specifications allow a maxi

Seite 36

AT-MR420TR and AT-MR820TR Installation Guide195.13 ns/meter. This cable internally consists of four shielded twisted pair wires with an overall shield

Seite 37 - Connectivity

Connectivity20Twisted Pair (RJ45) ConnectorFigure 11 shows a twisted pair cable with RJ45 connectors. For a 10Base-T link between a repeater and a Med

Seite 38 - Figure 8: Power Connector

AT-MR420TR and AT-MR820TR Installation Guide2110Base-T connections require Category 3, 4, or 5. In most cases, if a cable type is flat, it is typicall

Seite 39

MRx20TR(STP/UTP)_BookA Page 22 Thursday, April 3, 1997 5:24 PM

Seite 40

23Chapter 4TopologyStandalone TopologyFigure 12 shows a standalone topology. Four workstations are connected directly to the repeater through the repe

Seite 41

Topology24Figure 13: AT-MR820TR Four Cascaded RepeatersThe Four-Repeater Rule. The IEEE 802.3 standard provides general rules for 10Base-T cable leng

Seite 42

AT-MR420TR and AT-MR820TR Installation Guide25the termination switch. Figure 14 shows the location of the two-position 50 Ω Terminator switch. The swi

Seite 43

Topology26Backbone NetworksThe most straightforward topology is a backbone network. Figure 15 show a backbone network topology with the AUI port attac

Seite 44

AT-MR420TR and AT-MR820TR Installation Guide27second unit. A maximum of four repeaters (the four repeater rule) can be interconnected. The network eff

Seite 45 - Topology

v KLASSE 1 GERÄTE DIESE GERÄTE MÜSSEN GEERDET SEIN. Der Netzstecker darf nur mit einer vorschriftsmäßig geerdeten Steckdose verbunden werden. Ein unv

Seite 46 - BNC Terminator Switch

Topology28❑ In the MDI configuration — the slide switch is to the left — you can connect the 10Base-T port to another 10Base-T internal crossover port

Seite 47

AT-MR420TR and AT-MR820TR Installation Guide2910Base2 BackboneA maximum of 30 AT-MR420TR/AT-MR820TR Micro Repeaters can be connected in a network usin

Seite 48 - Backbone Networks

Topology30Fiber Optic BackboneBy attaching a fiber optic transceiver, the AUI port can connect your network to a fiber optic (10Base-FL/FOIRL) cable b

Seite 49

31Appendix ATechnical SpecificationsThe AT-MR420TR/AT-MR820TR SpecificationsPhysicalHeight 37.6 mm (1.55 in.)Width 332 mm (13 in.)Depth 112 mm (4.4 in.)

Seite 50

Technical Specifications32Diagnostic LEDsIndividual port link status (4/8)Individual port receive activity (4/8)Hub status (3), specifying:❑ Both Tran

Seite 51

AT-MR420TR and AT-MR820TR Installation Guide33ConnectorsNotice how the pins are numbered in Figure 20. Be sure to hold the connectors in the same orie

Seite 52

Technical Specifications34Straight-through WiringIf the twisted-pair link segment is to join two ports on a switch, and only one of the ports has an i

Seite 53 - Technical Specifications

AT-MR420TR and AT-MR820TR Installation Guide355 - 4 - 3 RuleIn addition to the requirements outlined in Chapter 3, Table 2, follow the “5-4-3 rule” to

Seite 54 - 10Base-T Pin Assignments

MRx20TR(STP/UTP)_BookA Page 36 Thursday, April 3, 1997 5:24 PM

Seite 55

37Appendix BGlossary10Base2—Also called thin Ethernet, thinnet or CheaperNet, a 10 MHz baseband specification. Cable impedance is 50 Ω and maximum coa

Seite 56 - Crossover Wiring

vi ELEKTRISK—KLASSE 1-UDSTYR DETTE UDSTYR KRÆVER JORDFORBINDELSE. Stikket skal være forbundet med en korrekt installeret jordforbunden stikkontakt.

Seite 57 - 5 - 4 - 3 Rule

Glossary38medium (coax cable) for data packet transmission. It provides for a level of error detection should that transmission be corrupted or impede

Seite 58

AT-MR420TR and AT-MR820TR Installation Guide39HUB/REPEATER—A hub is a central signal distributor. It is used in a wiring topology consisting of severa

Seite 59 - Glossary

Glossary40MEDIUM ATTACHMENT UNIT (MAU)—In a LAN, a device used in a data station to couple the DTE to the transmission medium.MEDIUM DEPENDENT INTERFA

Seite 60

AT-MR420TR and AT-MR820TR Installation Guide41SQE TEST—Commonly referred to as Heartbeat, is a special 802.3 signal sent by the MAU to the DTE to test

Seite 61

MRx20TR(STP/UTP)_BookA Page 42 Thursday, April 3, 1997 5:24 PM

Seite 62

43Appendix CTechnical Support Fax OrderName__________________________________________________________________Company _________________________________

Seite 63

MRx20TR(STP/UTP)_BookA Page 44 Thursday, April 3, 1997 5:24 PM

Seite 64

45Appendix DCentreCOM AT-MR420TR/AT-MR820TR Guide FeedbackPlease tell us what additional information you would like to see discussed in the guide. If

Seite 65 - Technical Support Fax Order

MRx20TR(STP/UTP)_BookA Page 46 Thursday, April 3, 1997 5:24 PM

Seite 66

47Appendix EWhere To Find UsFor Technical Support or ServiceLocation Phone FaxAsiaSingapore, Taiwan, Thailand, Malaysia, Indonesia, Korea, Philippines

Seite 67 - Feedback

vii ELEKTRISCHE —SNOERENGebruik een elektrisch snoer, maximum 4,5 meter lang, berekend voor ten minste 6 ampère, 250 V, uit HAR vervaardigd, met aan

Seite 68

Where To Find Us48AustraliaLindfield, NSWTel: (612) 416-0619, Fax: (612) 416-9764CanadaRexdale, OntarioTel: (416) 675-6738, Fax: (416) 675-0057Richmond

Seite 69 - Where To Find Us

49Appendix FIndexNumerics50 Ω terminator switch 4, 6802.3 transceiver 5Aambient temperature 7application specific integrated circuit(ASIC) 3Bb

Seite 70 - For Sales Information

50Index10Base2/AUI backbone switches 5AUI 17AUI network 9backbone 17backbone network 4BNC 19BNC network 9network backbone 15RJ45 9up

Seite 71 - Appendix F

viii ELECTRICITE —INFORMATION SUR LE CORDONUtiliser un cordon secteur de 4,5 mètres de long maximum, calibré à 6 ampères minimum, 250V, et fabriqué e

Seite 72

ix ASENNUSSOHJEETHUOMAUTUS : Nämä mallit on suunniteltu käytettäviksi VAAKA-asennossa. PYSTYASENNUSTA EI SAA TEHDÄ ilman Allied Telesyn -pystykiinnit