Overview ATI 9400 Configuration
Telesyn x400 - Installation Guide (Installation of ATI 9400)
1-2
.
TABLE 1-1
Listing of components with slot/position and configuration notes
No. Module Slot/Position Configuration Notes
A Service Module
(SM)
6, 8, 10 (left)
5, 7, 9,11 (right)
At least one is always configured. Unused slots must be configured
with FPFs.
Note: For information on SMs supported on the 9400 refer to the ATI
Component Reference.
B Control Module
(CM)
2, 4 (double) One card per shelf (occupies two slots).
Includes RS232 and OAM port. ETH0 and ETH1 are not used.
Note: For information on CMs supported on the 9400 refer to the ATI
Component Reference.
C Network Mod-
ule (NM)
Slot 0 and Slot 1 At least one is always configured. A Small Form Factor Pluggable
(SFP) module is required. An unused half-slot requires an FPH.
Note: For information on NMs supported on the 9400 refer to the ATI
Component Reference.
D Fan Controller 3 (half-slot) Fan Controller. Includes ALM IN port and ALM OUT port. COMM
port is currently not used.
E Power Entry
Module
Lower right of
chassis
Power Entry Module. Includes power feeds (H), signal ground, returns
(I), and A/B circuit breakers. (Signal ground is only used in an Isolated
Bonding Network.)
F Fan Module Center of chassis Fan Module.
G ESD ESD wrist strap connection point.
NA MAC Inside Chassis Included with chassis. Located on the front of backplane behind slots 8
and 10.
NA FPF Panels for Service
Module
Required when a Service Module slot is not used. Ensures proper air-
flow and EMI compliance.
NA FPH Panel for Network
Module
Required when half-slot for Network Module is not used. Ensures
proper airflow and EMI compliance.
H - - Mounting hole group.
I Ground Right side Primary ground connection